ve.can:nmea-2000:start
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
ve.can:nmea-2000:start [2021-12-09 10:24] – [3.2 NMEA 2000 instancing] mvader | ve.can:nmea-2000:start [2022-03-16 12:19] (current) – [3.4 DC Voltage compatibility] stefanie | ||
---|---|---|---|
Line 134: | Line 134: | ||
* Use the NMEA 2000 cable as the backbone. | * Use the NMEA 2000 cable as the backbone. | ||
- | * Run a separate drop cable separately to each Victron device [[https://nocache.victronenergy.com/ | + | * Run a separate drop cable separately to each Victron device [[https://www.victronenergy.com/ |
- | * Only terminate the NMEA 2000 backbone, do not terminate on the VE.Can | + | * Only terminate the NMEA 2000 backbone. Do not install a terminator in any of the VE.Can |
Or: | Or: | ||
Line 142: | Line 142: | ||
The first option is more aligned with the official N2K method. But, in case of multiple Victron products that need to be connected to the N2K network, will require more wire runs and definitively more NMEA2000 to VE.Can conversion cables. | The first option is more aligned with the official N2K method. But, in case of multiple Victron products that need to be connected to the N2K network, will require more wire runs and definitively more NMEA2000 to VE.Can conversion cables. | ||
- | ==== 3.4 Further reading on Victron and NMEA 2000 ==== | + | ==== 3.4 DC Voltage compatibility ==== |
+ | |||
+ | The Victron VE.Can network accepts 9 to 70VDC. | ||
+ | |||
+ | The NMEA-2000 network used to be 9 to 16VDC, which is, or will be, expanded to also include 24V. Which means that some NMEA-2000 devices are 9 to 16VDC, some are 9 to 30VDC, and some allow higher voltages. | ||
+ | |||
+ | Also, the Victron VE.Can network will (in most cases) be powered with battery voltage. So for a 48V system, the voltage on the VE.Can network **exceeds** the NMEA-2000 accepted voltage levels. | ||
+ | |||
+ | Therefore, it is important to **not** connect those power cables. | ||
+ | |||
+ | The Victron cable used to connect both networks together, the [[https:// | ||
+ | |||
+ | ==== 3.5 Further reading on Victron and NMEA 2000 ==== | ||
* [[https:// | * [[https:// | ||
Line 152: | Line 164: | ||
==== 4.1 Raymarine & EmpirBus ==== | ==== 4.1 Raymarine & EmpirBus ==== | ||
- | Besides using NMEA 2000 and/or the Lighthouse App, integration onto Raymarine MFDs can also be done with an [[http://www.trigentic.com/# | + | Besides using NMEA 2000 and/or the Lighthouse App, integration onto Raymarine MFDs can also be done with an [[https://www.empirbus.com/# |
- | In the [[http:// | + | In the [[https:// |
- | Next, use the [[http:// | + | Next, use the [[http:// |
The EmpirBus system requires the data instance of battery status and dc detailed status to be unique when using multiple sources. ([[ve.can: | The EmpirBus system requires the data instance of battery status and dc detailed status to be unique when using multiple sources. ([[ve.can: |
ve.can/nmea-2000/start.1639041898.txt.gz · Last modified: 2021-12-09 10:24 by mvader