Both sides previous revisionPrevious revision | |
ve.can:changing_nmea2000_instances [2023-04-13 20:50] – [1.3 Recommend instancing setup for main MFD brands] mvader | ve.can:changing_nmea2000_instances [2023-06-28 13:32] (current) – Update links sloges |
---|
There various types of instances, and for marine systems are two that matter: the Device instance and the Data instance. The data instance goes by various different names, like Fluid instance, Battery instance and DC instance. | There various types of instances, and for marine systems are two that matter: the Device instance and the Data instance. The data instance goes by various different names, like Fluid instance, Battery instance and DC instance. |
| |
Details and differences of each type are explained in detail in the [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/marine-mfd-integration-by-nmea2000.html|Cerbo GX manual, NMEA 2000 chapter]]. | Details and differences of each type are explained in detail in the [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/marine-mfd-integration-by-nmea-2000.html|Cerbo GX manual, NMEA 2000 chapter]]. |
| |
**WARNING**: whilst it is possible to change the Battery and DC instances on a Skylla-i battery charger, changing those will render it impossible for a GX device to properly read the data. This is because the GX device expects the charger's output one to be on Battery & DC instance 0, output two on Battery & DC instance 1, and output three on Battery & DC instance 2. Changing the fluid instance, as well as other data instances for PGNs transmitted by a GX device on a NMEA2000 network using its NMEA2000-out feature, is no problem. | **WARNING**: whilst it is possible to change the Battery and DC instances on a Skylla-i battery charger, changing those will render it impossible for a GX device to properly read the data. This is because the GX device expects the charger's output one to be on Battery & DC instance 0, output two on Battery & DC instance 1, and output three on Battery & DC instance 2. Changing the fluid instance, as well as other data instances for PGNs transmitted by a GX device on a NMEA2000 network using its NMEA2000-out feature, is no problem. |
* [[ve.can:nmea-2000:start]] | * [[ve.can:nmea-2000:start]] |
* [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication white paper]] | * [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication white paper]] |
* [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/marine-mfd-integration-by-nmea2000.html|Cerbo GX manual, NMEA 2000 chapter]] | * [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/marine-mfd-integration-by-nmea-2000.html|Cerbo GX manual, NMEA 2000 chapter]] |
* [[https://community.victronenergy.com/topics/NMEA%202000%20-%20N2K.html|NMEA2000 related discussions on Victron Community]] | * [[https://community.victronenergy.com/topics/NMEA%202000%20-%20N2K.html|NMEA2000 related discussions on Victron Community]] |
| |